MUMBAI, India, Nov. 23 -- Intellectual Property India has published a patent application (202641089088 A) filed by Jeppiaar Institute Of Technologyjit on July 22, 2026, for Novel System, Design Na Method Of Plant Diseases Detection Using Image Processing With Data Capturing By Drone.

Inventors include Dr. J. Venu Gopala Krishnan; Dr. T. Sripriya; Dr. W. Nancy; Dr. M. Benisha; M. Indumathi; Bharathi M; Karthika. T; M. Nithya; S. Revathy; and M. Sudhagar.

The application for the patent was published on November 20, 2026, under issue no. 47/2026.

Abstract: 6. ABSTRACT OF THE INVENTION The patent disclosure covers Novel System, Design and Method of Plant Diseases Detection Using Image Processing with Data Capturing by Drone. This patent disclosure covers a Novel System design of a data capturing drone. In the existing system tormenter virus and a few diseases causes infection to plant with loss of quality and amount production. Agriculture is the most significant and ancient occupation in Republic of India. Hence proper care of plants is important. This patent disclosure is proposing to capture the field by using drone and capture images of plant leaves. Then with the use of MATLAB software, image segmentation process is done by using K-Means Clustering and Aniso - Diffusion filter for filtered images. The code without and with filtered images are run to check the accuracy. The accuracy of the filtered image is greater than accuracy of the unfiltered image. A Quad copter captures the pictures with the plants affected by fungi, virus and microorganism on plants. Image processing is used for persecutor management detection of insects, identification of nutrient deficiencies. With the assistance of image processing, automatic detection of varied diseases is analyzed. Preeclampsia, a condition associated with hypertension during pregnancy, affects between 5 and 8% of pregnant women worldwide and leads to upward of 70,000 deaths from related complications. This condition typically presents after 20 weeks gestation and can cause multi-organ failure in the expecting mother, leading to premature birth and thereby increasing risk of morbidity and mortality to both the fetus and the expecting mother. Oscillometry is the blood pressure measurement principle of most automatic cuff devices. The oscillogram is measured, and BP is then estimated via an empirical algorithm. The external pressure of an artery is swept between supra-systolic and sub-diastolic BP levels, and the external pressure is measured and high-pass filtered to yield oscillations. Since the arterial compliance is dependent on transmural pressure, the peak-to-peak amplitude of the blood volume oscillations varies with the external pressure. BP is then estimated from the oscillation amplitude vs. external pressure function via an algorithm.

Disclaimer: Curated by HT Syndication.