MUMBAI, India, Nov. 13 -- Intellectual Property India has published a patent application (202641134101 A) filed by Ramakrishna Garlapati; Dr. M. V. Nagabhushanam; Dr. Sreevidya Puvvala; M. Beena Devi; Sk Sarmas Sri; Srilakshmi Avutu; Ch. Laxmi Swarupa; Majjari Venkata Padma; Duddu. Swarupa Rani; and Yerragopu Nagasurekha on November 07, 2026, for Closed-Loop Implantable Neuromodulation System Responsive To Oral Acarbose Events In Diabetic Neuropathy.

Inventors include Ramakrishna Garlapati; Dr. M. V. Nagabhushanam; Dr. Sreevidya Puvvala; M. Beena Devi; Sk Sarmas Sri; Srilakshmi Avutu; Ch. Laxmi Swarupa; Majjari Venkata Padma; Duddu. Swarupa Rani; and Yerragopu Nagasurekha.

The application for the patent was published on November 13, 2026, under issue no. 46/2026.

Abstract: Abstract The closed-loop neuromodulation system comprises a glucose sensor, an oral acarbose event termina, and an implantable controller. The controller receives glucose measurements from the sensor and reported intake records from the event terminal. It uses glucose measurements to determine whether to request a stimulation burst and uses a paired acarbose intake record and meal record to determine how much stimulation charge may be delivered. A charge monitor, an output gate, and a pulse driver cooperate to enforce the selected charge ceiling at a neural electrode. In one embodiment, the oral acarbose event terminal receives an entry identifying a reported oral intake of acarbose and the time associated with that intake. A meal record identifies a meal and its associated time. The controller may pair the records using a common meal identifier or a programmed temporal relationship between the reported intake and the meal. The pairing establishes that an intake has been reported in association with the meal. The controller can therefore select the reduced ceiling without requiring a measurement of acarbose concentration. Upon accepting the pairing, the controller selects a reduced rolling-window stimulation charge ceiling and initiates a minimum observation interval. The ceiling specifies the maximum cumulative stimulation charge permitted over a window of programmed duration. At each proposed burst, the charge monitor determines the charge already delivered within the window immediately preceding the proposed delivery time. This calculation includes charge delivered before the pairing if that delivery still falls within the window. When a valid glucose measurement satisfies a programmed stimulation condition, the controller issues a burst request. The output gate determines the available charge by subtracting the charge already delivered within the rolling window from the selected ceiling, with a lower bound of zero. If the available charge accommodates the requested burst, the gate permits the pulse driver to deliver it through the neural electrode. If the requested burst exceeds the available charge, the gate may permit fewer pulses, provided that their combined charge remains within the available amount. This sequence allows glucose measurements to govern individual burst requests while the reported acarbose–meal event governs the cumulative electrical output available to those requests.

Disclaimer: Curated by HT Syndication.